Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
product picture of the ultrasonic flow measurement instrument FLOWSIC100 Flare-XT

FLOWSIC100 Flare-XT
ultrasonic flow measurement instrument

Reliable gas flow measurement on flare stacks in petroleum refineries, chemical plants and natural gas processing

IFL1FX
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Ultrasonic transit time difference measurement

  • Measured variables

    Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity

  • Measuring range

    0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)

  • Max. Measurment error

    Volumetric flow, a. c.; 1 % ... 5 %
    Related to the measured value (in the range ≥ 0.3 m/s to measuring range end value)
    0,5 % ... 1,5 % with spool piece and flow calibration
    Related to the measured value (in the range ≥ 1 m/s to calibration range end value)
     
    Mass flow rate a.c.; 2 % ... 5.5 %
    Related to the measured value (in the range ≥ 0.3 m/s to measuring range end value)
    1,5 % ... 2 % with spool piece and flow calibration
    Related to the measured value (in the range ≥ 1 m/s to calibration range end value)

  • Medium temperature range

    -196 °C ... +280 °C
    (-320 °F ... +536 °F)

  • Operating pressure range

    CL150 device flange 1 ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    PN25 device flange (optional) 1 ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    CL300 device flange (optional) 1 ATEX/IECEx: 20 bar(g)
    CSA: 16 bar(g)
    1 Temperature dependent. For details, see section Application ranges.

  • Nominal pipe size

    1-path measurement 4 ″ ... 86 ″
    2-path measurement 12 ″ ... 86 ″
    Other nominal sizes on requestOther nominal sizes on request

  • Conformities

    ATEX: 2014/34/EU
    EMC: 2014/30/EU
    RoHS: 2011/65/EU
    PED: 2014/68/EU

  • Hazardous area approvals

    IECEx:
    Zone 1: Ex db eb ia IIC T4 Gb
    Zone 1: Ex db ia IIC T4 Gb
    Zone 2: EX ec ia IIC T4 Gc
     
    ATEX:
    Zone 1: II 2G Ex db eb ia IIC T4 Gb
    Zone 1: II 2G Ex db ia IIC T4 Gb
    Zone 2: II 3G Ex ec ia IIC T4 Gc
     
    NEC/CEC (US/CA):
    Zone 1: Ex d ia IIC T4 Gb
    Zone 1: Class I, Zone 1, AEx d ia IIC T4 Gb
    Zone 1: Class I, Division 1, Groups B, C, D, T4
    Zone 2: EX ec ia IIC T4 Gc
    Zone 2: Class I, Zone 2, AEx ec ia IIC T4 Gc
    Zone 2: Class I, Division 2, Group A, B, C and D, T4

  • Outputs

    Up to 6 outputs when using I/O modules (Option)
    16 bit:
    4 ... 20 mA
    7 V DC ... 30 V DC
    In accordance with NAMUR NE43
    Passive, galvanically isolated
    Reverse polarity protection

  • Digital Outputs

    Switching output:
    Up to 6 outputs when using I/O module (option)
    Electrically isolated
    Max. current: 70 mA
    Max. switching frequency: 50 Hz
    Max. input voltage: 30 V DC
    Max. saturation voltage at output: 0.5 V DC
    Switchable Namur/open collector
    Reverse polarity protection
     
    Digital output/Frequency output:
    Up to 12 digital outputs when using I/O modules (option)
    Electrically isolated
    Max. current: 50 mA
    Max. switching frequency: 10 kHz
    Max. input voltage: 30 V DC
    Max. saturation voltage at output: 1.8 V DC
    Switchable Namur/open collector
    Reverse polarity protection

  • Digital communication

    ASCII RS-485
    RTU RS-485
    TCP
    PROFUBUS DP
    HART